Artikelnr: 86-40100105619

Vaf ODME System OILCON MK6M

SHIPS PARTICULARS
Hull no....
Vessel type: Product/Chemical Tanker
Class:...
Owner:...
Ship speed: Speed log is 200 P/NM
Over board line: Diameter ...... A (Inner dia. .....mm)
Flow rate max.: ..... m³/hr
Sample probe(s): 1 piece
Onboard Current: ......hz

PRODUCT SPECIFICATIONS
VAF Instruments Oilcon Mark 6M, Oil Discharge Monitoring and
Control system in accordance with IMO resolution MEPC.108(49),
Regulation 31 Annex I of Marpol 73/78 (2011 consolidates edition)
MEPC108(49) as amended by IMO resolution MEPC.240(65).

Ex proof classification according to:
Ex II(1)G [Ex ia] IIB (interface)
Ex II 1 G Ex ia IIB T4 (detector cell)

Consisting of:
1 off Main Control Unit 24 VDC
1 off Electro Pneumatic Unit, 230 Vac, 50/60Hz, suitable for maximum
2 sample valves, with built-in safety barrier for one flow meter
1 off Air Supply Unit
1 off Air Supply Unit Window Wash Pump
1 off Skid assembly with 15 mm pipe couplings
1 off Isolating valve
1 off Coupling with injection point
1 off Coupling with grab cock
1 off Sample pump /bulkhead gland with 15 mm pipe couplings
1 off Welding-ring for easy mounting of new Sample Point
1 off Gasket
1 off Starter box for Sample Pump
1 off Sample valve assembly with 15 mm pipe couplings
1 off Sample probe with 15 mm pipe coupling, material: 316SS
1*) off Flowmeter(DP/I transmitter) with bracket and manifold for
maximum dp range lower than1000 mbar
2*) off Ball valves
1*) off Orifice Plate: Size to be advised based on info overboard line and flow rate.
1 off Fresh water pressure reducing valve
1 off 10 m cable IC02 for connection EPU to Skid
1 off Box containing the following spare part kit:
1 Sample pump lubricant 500 ml
2 O-rings ID 53.70x1.78mm
2 Fuses 630 mA
1 Cleansing brush

Standard cable connections:
Cable EPU to MCU: M20x1.5 cable diameter 6-12mm
Cable EPU to Skid: M20x1.5 cable diameter 10-14mm
Cable EPU to starterbox: M20x1.5 cable diameter 6-12mm
Cable EPU to Dp/I tx: Pg 13,5Ex cable diameter 6-12mm
Cable EPU to power supply: M20x1.5 cable diameter 6-12mm

Paint: Munsell 7,5 BG 7/2 (standard)

The VAF Oilcon ODME system complies to the latest regulations regarding
the carriage of Biodiesel according to IMO resolution MEPC.108(49), regulation
31 Annex I of Marpol 73/78 (2011 consolidates edition) MEPC108(49) as amended
by IMO resolution MEPC.240(65).

The OILCON MK6M has a DNV type approval, please go to www.sikama.se.
For more Technical details on the new MK6M, please go to www.sikama.se.

Installation
*Shipyard/ships engineer is responsible for physical mounting of the equipment, running of all
cable and terminations. Included with Mark6M ODME is an adapter flange to be installed on the
current bulkhead sample pump ring. This makes you able to install the smaller Mark6M sample
pump without any hot work to be carried out. Refer to technical manual delivered with order
and available via www.sikama.se for details on installation of each component. Installation of
ODME system, under normal circumstances, can be completed in two (2) days.

Commissioning of the system can be carried out by a VAF Instruments technician and in normal
circumstances can be completed in one (1) day.
Commissioning hours for the ODME are not included in the price.